12V Battery Run Time Calculator

A 12 V battery rated at 100 Ah stores 1,200 Wh, enough to run a 90 W load for about 6 hours. That assumes 50% depth of discharge and a 90% efficient inverter, and a lithium pack of the same size stretches past 9 hours.

Enter your battery amp hours, voltage and the watts your gear draws to see how many hours it will run, with depth of discharge and inverter loss included.

By the Lelifi editors ·

Key takeaways

Run time math for a 100 Ah, 12 V AGM battery12 V x 100 Ah = 1,200 Wh storedx 50% depth of discharge = 600 Wh usablex 90% inverter efficiency = 540 Wh at the load540 Wh / 90 W load = 6.0 hours= 6 hours of run time
A 100 Ah, 12 V AGM battery stores 1,200 Wh, of which 540 Wh reaches a 90 W load after depth of discharge and inverter loss, giving 6 hours of run time.
Where the 1,200 stored watt hours end up540 Wh to the load60600 Wh left in the batteryDelivered at 90% inverter efficiencyInverter heatHeld back by the 50% discharge limit
Of 1,200 stored watt hours, 600 Wh stay in the battery under a 50% discharge limit, 60 Wh become inverter heat and 540 Wh reach the load.
On this page
  1. How to calculate 12V battery run time
  2. Worked example: a 100 Ah battery running a 90 W load
  3. Run time by load size
  4. Depth of discharge: the biggest lever you control
  5. Inverter efficiency and phantom loads
  6. Amp hour loads, Peukert losses and cold weather
  7. Mistakes that make the estimate wrong

How to calculate 12V battery run time

Run time comes down to one comparison: the energy your battery can deliver, and the power your gear consumes. A 12V battery's size is printed in amp hours, but loads are rated in watts, so the first job is putting both on the same footing. The conversion is short: 12 V x 100 Ah = 1,200 Wh.

From there the math runs in three moves:

Put together, the formula is: run time in hours equals amp hours x volts x depth of discharge x efficiency, all divided by load watts. The calculator above performs each step and shows the intermediate numbers, so you can see whether a bigger battery, a lighter load or a lithium upgrade buys the most hours per dollar.

Worked example: a 100 Ah battery running a 90 W load

Picture a 100 Ah, 12 V AGM battery in a cabin, running a 60 W television and a 30 W internet router through an inverter. The two loads together draw 90 W.

Step one, stored energy: 12 V x 100 Ah = 1,200 Wh. Step two, usable energy: AGM chemistry lasts longest when cycled to 50%, so 1,200 x 0.50 = 600 Wh. Step three, inverter loss at 90% efficiency: 600 x 0.90 = 540 Wh reaches the gear. Step four, time: 540 divided by 90 gives 6 hours of television and browsing.

The same battery powering the 90 W load directly at 12 V, with no inverter in the path, keeps the full 600 Wh and lasts 6.7 hours. That 40 minute gap is the inverter earning its keep, and it runs whether the television is on or not. A typical idle draw of 6 to 10 W means an inverter left switched on overnight can quietly flatten a third of this battery by itself.

Run time by load size

Using the same 540 Wh of usable energy, every load lands somewhere on this table. The wattages are continuous draws, not nameplate peaks.

LoadTypical exampleRun time on 540 Wh
20 WLED lighting27 hours
60 WTelevision9 hours
90 WTelevision and router6 hours
150 WDesktop computer3.6 hours
300 WBlender or large fridge while running1.8 hours
600 WMicrowave0.9 hours, about 54 minutes

Notice the shape of the table: halving the load doubles the run time. Also notice which loads matter most. A microwave at 600 W looks alarming, but it runs for four minutes at a time, so a week of cooking costs less than one hour of the desktop computer. A fridge cycles on and off, so its average draw is often a third of its nameplate, and the honest way to size for it is watts times the duty cycle.

Depth of discharge: the biggest lever you control

Depth of discharge decides how much of the stored energy you can take without paying for it in battery lifespan. Lead acid chemistry wears out fast when pulled deep, while lithium barely notices. On the same 1,200 Wh battery, the usable energy looks like this.

ChemistrySafe daily dischargeUsable energy
Flooded lead acid50%600 Wh
AGM50%600 Wh
Gel50%600 Wh
Lithium LiFePO480%960 Wh

The lithium row is the reason off-grid systems keep moving that direction: 1,200 x 0.80 = 960 Wh, which is 60% more working energy from a battery of the same printed size, with far more charge cycles behind it. The Department of Energy's explanation of lithium ion batteries covers why the chemistry tolerates deep cycling, and Battery University's guide to prolonging lead acid batteries documents the cycle counts at each depth. If your loads are fixed, choosing chemistry changes the answer more than any other single input on this page.

Inverter efficiency and phantom loads

Every watt that crosses from 12 V DC to household AC passes through a conversion, and conversions are never free. The table below holds the load at 100 W and varies only the path between battery and gear.

PathEnergy reaching the loadRun time
Direct DC, no inverter600 Wh6.0 hours
Premium inverter, 95%570 Wh5.7 hours
Good inverter, 90%540 Wh5.4 hours
Budget inverter, 85%510 Wh5.1 hours

The spread between the best and worst row is a bit over an hour on this battery, and it grows with system size. The sneaky loss is not the conversion itself but the idle draw: an inverter switched on and doing nothing still pulls 6 to 15 W around the clock. Over a day that is 150 to 360 Wh, which on this 100 Ah battery is a quarter to a third of everything it can safely give. Switch the inverter off at the battery when nothing is plugged in, and the arithmetic on this page suddenly starts matching what you see on the voltmeter.

Amp hour loads, Peukert losses and cold weather

Many 12V loads are rated in amps rather than watts: a fridge compressor at 4 A, a water pump at 5 A, a light circuit at 2 A. For these, work in amp hours directly. Usable amp hours divided by load amps gives hours: a 100 Ah battery cycled to 50% has 50 Ah to give, so 50 divided by 4 is 12.5 hours of compressor time.

Lead acid adds one more wrinkle called the Peukert effect: the faster you pull current, the less total capacity the battery delivers. Discharged gently over 20 hours, a 100 Ah battery gives close to its full rating. Drained at 25 A, the same battery gives closer to 65 Ah before it hits the floor. Lithium does not behave this way, which is another reason the same printed amp hours run longer in a lithium pack under heavy loads.

Temperature stacks on top of everything else. Around freezing, a flooded battery delivers roughly 80% of its rating, and deep cold pushes that toward 60%. Size the battery for the coldest night it will work, not the datasheet's 77 F ideal.

Mistakes that make the estimate wrong

Most bad run time estimates trace back to one of five inputs.

Get the inputs right and the calculator's answer usually lands within 10% of a real discharge test. When it does not, the battery itself, rather than the math, is usually the part that has changed.

Treat every result as a planning estimate. Battery condition, temperature and load behavior vary from day to day, so confirm critical systems with a real discharge test before you rely on them.

Frequently asked questions

How long will a 12V 100Ah battery run a 100W load?

About 5.4 hours through a good inverter. The battery stores 1,200 Wh, 50% depth of discharge leaves 600 Wh, and a 90% efficient inverter delivers 540 Wh, so 540 / 100 = 5.4 hours. Feeding the load directly at 12 V without an inverter stretches it to 6 hours.

How many watts is a 12V 100Ah battery?

1,200 watt hours. Multiply volts by amp hours: 12 x 100 = 1,200 Wh. That is the energy stored when the battery is new and fully charged, before depth of discharge and conversion losses come out.

How long will a 12V battery last with a 5 amp draw?

A 100 Ah lead acid battery gives you 50 usable amp hours at 50% depth of discharge, so 50 / 5 = 10 hours. A same size lithium pack allows about 80 usable amp hours, which is 16 hours at the same draw.

Can I use 100% of a 12V battery's capacity?

Lithium iron phosphate cells tolerate 80% to 100% discharge without much harm. Flooded, AGM and gel lead acid batteries do not: pulling them below 50% regularly can cut their cycle life by more than half, which is why the calculator defaults to 50% for lead acid.

How long will a 12V battery run a fridge?

A 12 V compressor fridge draws 40 to 60 W while running but cycles off, so its average draw lands near 15 W over a day. On the 540 Wh of usable energy in the worked example above, that is about a day and a half, and closer to two days in cool weather.

Does a bigger inverter give longer run time?

No, and it usually gives less. Inverter capacity does not add energy, and larger units idle at a higher draw, sometimes 15 W or more. Match the inverter to the load with some headroom rather than buying the biggest one on the shelf.

How does temperature change battery run time?

Cold cuts lead acid capacity hard: at 32 F a flooded battery holds roughly 80% of its room temperature rating, and near 0 F closer to 60%. Lithium cells lose less but must not be charged below freezing. Heat ages every chemistry faster.

What does 50% depth of discharge mean?

It means you plan to take half the stored energy out before recharging. On a 100 Ah battery that is 50 Ah, or 600 Wh at 12 V. Staying near that line is what lets a lead acid battery reach several hundred cycles instead of a few dozen.

How long will a 12V 7Ah battery run a 10W device?

Roughly 4 hours. The small battery stores 12 x 7 = 84 Wh, half of that is usable on lead acid, and 42 / 10 = 4.2 hours through a lossless path. Through a 90% inverter it drops to about 3.8 hours.

How do I convert amp hours to watt hours?

Multiply amp hours by the battery's nominal voltage. A 100 Ah battery at 12 V is 1,200 Wh, and the same 100 Ah at 24 V is 2,400 Wh. That is why two 6 V batteries wired in series still store the same energy as one 12 V of the same amp hour rating.

Why does my battery die faster than the calculation says?

Four usual suspects: the battery is older than its rating, the load draws more than its nameplate, an inverter idles away watt hours between uses, or the discharge current is high enough that Peukert losses shrink the effective capacity of a lead acid battery.

How long will a 12V battery run LED lights?

A long time. Ten watts of LED lighting runs about 54 hours on the 540 usable Wh in the example, and a single 5 W bulb stretches past 100 hours. Lighting is one of the few loads where a 100 Ah battery feels enormous.

What size battery do I need for 8 hours at 60W?

The load needs 480 Wh over 8 hours. Work backwards: 480 / 0.90 inverter efficiency = 533 Wh, and at 50% depth of discharge that is 1,067 Wh of stored energy, which is about 89 Ah at 12 V. A 100 Ah battery covers it with margin.

Is a 24V setup better than 12V for run time?

Not by itself. Two 12 V 100 Ah batteries store 2,400 Wh whether you wire them for 12 V or 24 V. The 24 V wiring halves the current for the same load, which reduces cable losses and helps larger loads, but the energy and the run time stay the same.

Spotted a wrong number or a broken result?

More Date Time tools

See all Date Time tools