Generator Size Calculator
A 3,200-watt load with a fridge surging to 2,200 watts needs a 5,000-watt generator, because the motor adds 1,500 watts at startup. Add 25% headroom and the surge target is 5,875 watts. Running watts alone would point you at a 4,000-watt unit that trips the moment the compressor kicks in.
| Generator to buy (running watts) | |
| Surge capacity that size gives you | |
| Surge your load needs | |
| Total surge with the motor starting | |
| Extra starting watts from that motor | |
| Running watts with headroom | |
| Running watts on the list | |
| Headroom added |
Estimate only, at sea level and moderate temperature. Derate about 3% per 1,000 feet of elevation. All calculations run in your browser, and nothing you type is uploaded or stored.
Add the running watts of everything you want on at once, enter the biggest motor's starting watts, and see the generator size that covers the surge.
Key takeaways
- Motors pull 2 to 3 times their running watts for a second at startup
- A 3,200-watt load with a 2,200-watt fridge surge sizes at 5,000 watts
- Add 20% to 30% headroom for heat, elevation and age
- A 5,000-watt unit burns about 0.5 gallons an hour at half load
- A transfer switch needs a licensed electrician and usually a permit
On this page
Two numbers decide the size
Two numbers decide the size of a generator, and mixing them up is the most common buying mistake. Running watts, sometimes called continuous watts, is what the machine can hold all day. Starting watts, or surge watts, is the short burst it can deliver for a second or two when a motor kicks on.
Every appliance with a motor asks for a burst at startup. A refrigerator that runs on 700 watts can pull 2,200 watts for the half second its compressor starts. A well pump that runs on 1,000 watts can pull 2,000. The generator has to survive that burst, and it has to do it while everything else is already running.
So the rule is simple to state: add up the running watts of everything you want on at the same time, then add the extra starting watts of the single biggest motor. Size to that total plus a margin, and you will not be the person whose generator trips every time the fridge cycles.
Add up everything you want to run
Start with a list. Walk the house and write down what you cannot do without for a few days: the fridge, the furnace blower, a few lights, the router, phones, and one thing that makes the wait bearable. Leave out what you can live without, because every 1,000 watts costs money and fuel.
| Appliance | Running watts | Starting watts |
|---|---|---|
| Refrigerator (18 cu ft) | 700 | 2,200 |
| Furnace blower (gas heat) | 800 | 1,600 |
| Well pump, 1/2 hp | 1,000 | 2,000 |
| Sump pump, 1/3 hp | 800 | 1,600 |
| Window AC, 10,000 BTU | 1,200 | 1,800 |
| Central AC, 3 ton | 3,500 | 6,000 |
| Microwave | 1,000 | 1,000 |
| Coffee maker | 900 | 900 |
| LED bulbs, 10 of them | 90 | 90 |
| TV and internet router | 200 | 200 |
| Laptops and phones | 300 | 300 |
| Space heater | 1,500 | 1,500 |
| Garage door opener | 550 | 1,100 |
Two cautions on the numbers. First, a nameplate rating is usually higher than what the appliance draws in normal use, so check the label on the back or the manual rather than a rule of thumb. Second, anything that heats with a resistance element, like a space heater, a coffee maker or an electric water heater, draws its full rating the whole time it is on, with no surge and no duty cycle.
Motors pull 2 to 3 times their rating at startup
Motors are the reason a generator has two ratings at all. An induction motor pulls a locked-rotor current for a fraction of a second as it comes up to speed, and that current is two to three times the running current. The bigger the motor, the bigger the multiple and the longer the burst.
This matters because the burst is not averaged out. If the fridge, the furnace and the well pump all decide to start in the same second, the loads stack. In practice they do not, which is why the sizing rule counts only the largest motor at startup rather than all of them.
Put a number on it. The table in the previous section shows the pattern: a refrigerator compressor starts at about 3.1 times its running watts, while a furnace blower, a sump pump and a garage door opener start at about 2 times. The bigger the motor and the heavier the load it turns, the larger the multiple and the longer the burst lasts.
Soft-start kits change the math. A soft starter ramps a compressor or a pump up over a second instead of slamming it on, which can cut the startup burst by half or more. On a house with a big AC or a deep well pump, a $300 soft starter can be the difference between a 7,500-watt unit and an 11,000-watt one, and it pays for itself at the fuel pump.
Worked example: a 3,200-watt load
Here is a real list for a small house in a cold climate. Everything on it runs at once during an outage, and the fridge is the biggest motor.
| Load | Running watts |
|---|---|
| Refrigerator | 700 |
| Furnace blower | 800 |
| Well pump | 1,000 |
| LED lights, 20 bulbs | 200 |
| TV, router and modem | 200 |
| Laptops and phone chargers | 300 |
| Total running | 3,200 |
The fridge runs on 700 watts and starts at 2,200, so its extra starting load is 1,500 watts. Add that to the 3,200 running watts and the surge the generator has to survive is 4,700 watts.
Now the margin. Multiply both figures by 1.25: 4,000 watts of running capacity and 5,875 watts of surge. Portable units list a surge rating about 20% above their running rating, so a 5,000-watt unit with a 6,000-watt surge covers the 5,875 target with a little room. That is the answer: 5,000 running watts, not 3,200 and not 8,000.
Run the same math on a smaller setup, a fridge, a sump pump, lights and charging at 1,800 running watts with a 1,000-watt pump start. The surge is 2,300, the target after headroom is 2,875, and a 2,500-watt unit with a 3,000-watt surge handles it. On a bigger house with 8,000 running watts and a 3,000-watt pump start, the target lands at 12,500 watts of surge and the recommendation moves to 10,500 watts or the next size up.
Why the 25% headroom is not padding
The 25% margin is not padding for the salesman. It covers four things that all show up in the first hour of an outage.
- Ratings are optimistic. A 5,000-watt generator makes 5,000 watts at sea level on a 60 degree day. At 5,000 feet of elevation it makes about 15% less, and at 100 degrees it derates again.
- Loads creep. The list you wrote in July grows in January, when the space heater and the furnace blower both want to run.
- Age costs watts. A unit with 400 hours on it and a dirty air filter will not hit its sticker number.
- Starting is not clean. Voltage sags during a motor start, and electronics on the same circuit notice. Margin keeps the lights steady.
Twenty percent is the minimum sensible margin and 30% is comfortable for a house with a well pump. Below 10% you are buying a unit that will nuisance-trip on the first cold morning, and nuisance trips are how people end up running extension cords to a generator at 2 a.m.
Portable, inverter or standby
Three kinds of generator cover most homes, and the size you need usually points at one of them.
Portable open-frame. 3,000 to 8,500 watts, loud at 72 to 78 dB, burns gasoline, and needs to sit outside. Cheapest per watt by a wide margin. Fine for a fridge, lights, a furnace blower and a well pump.
Inverter portable. 2,000 to 7,000 watts, quiet at 52 to 62 dB, clean power that will not upset a furnace control board or a laptop, and parallel kits let two units run together. Costs 30% to 50% more per watt and is the right pick for electronics and for camping.
Standby. 7,000 to 22,000 watts, wired to a transfer switch and fueled by natural gas or propane, starts on its own within seconds. Installed cost runs $3,000 to $12,000 depending on size and electrical work. It is the only option that covers a central AC and an electric water heater at the same time.
Match the type to the load before you match the price. A 5,000-watt open-frame unit and a 5,000-watt inverter do the same job on paper and feel completely different in a driveway at midnight.
The transfer switch is not a DIY job
Connecting a generator to house wiring is not a cord-and-outlet job. It needs a transfer switch, and a transfer switch needs an electrician, a permit and an inspection in most jurisdictions.
The transfer switch does one thing: it disconnects the house from the utility before the generator connects. Without it, the generator backfeeds the line and puts 240 volts on wires a utility crew believes are dead. That is the failure mode behind most generator electrocutions, and it is why the illegal double-male cord, often called a suicide cord, is banned everywhere.
There are two common setups. A manual transfer switch with a handful of labeled circuits costs $300 to $800 installed and lets you choose what runs. An interlock kit on the main panel is cheaper and covers the whole panel, but every circuit is live at once, so the load calculation matters more, not less.
Carbon monoxide is the other hazard. A generator belongs outdoors, at least 20 feet from doors, windows and vents, with the exhaust pointed away. Never in a garage, a basement, a crawlspace or an attached shed, even with the door open. The Ready.gov power outage guide and the OSHA electrical safety pages both spell out the clearance and backfeed rules, and they are worth ten minutes before the storm rather than after.
Fuel, runtime and noise at each size
Fuel and runtime are where the size decision turns into a weekly chore. A bigger generator is not just more expensive to buy, it burns more every hour whether or not you use the capacity.
| Running watts | Fuel at half load | Hours on 6 gallons | Noise |
|---|---|---|---|
| 2,500 W | 0.30 gal/hr | 20 hours | 68 dB |
| 5,000 W | 0.50 gal/hr | 12 hours | 74 dB |
| 7,500 W | 0.75 gal/hr | 8 hours | 76 dB |
| 10,500 W | 1.00 gal/hr | 6 hours | 78 dB |
A 5,000-watt unit at half load gets through a 12-hour night on a little under 6 gallons, which is about $20 at $3.40 a gallon. The same house on a 10,500-watt unit burns roughly twice that to do the same work, because a large engine idling at 20% load is inefficient.
Dual-fuel units run on propane with a 10% to 20% loss of rated watts, and a 20 lb tank holds about 4.7 gallons of propane, enough for roughly 5 hours at half load on a 5,000-watt unit. Propane stores for years and does not go stale like gasoline, which matters when the generator sits in a shed for 11 months. Keep 10 gallons of treated gasoline or two full propane tanks, and test the unit under load twice a year. The Department of Energy publishes the efficiency figures behind those derates if you want the detail.
Frequently asked questions
What size generator do I need for a refrigerator?
About 2,500 running watts covers a fridge, a few lights and phone charging. The fridge itself runs at 700 watts but pulls 2,200 at startup, so a 2,200-watt unit is the floor and 2,500 gives margin.
How many watts does a 5,000-watt generator put out?
5,000 running watts and roughly 6,000 surge watts, at sea level and moderate temperature. Expect about 15% less at 5,000 feet of elevation and a little less on a 100 degree day.
Why do motors need 2 to 3 times their running watts to start?
An induction motor draws locked-rotor current until it comes up to speed. That burst lasts under a second but reaches two to three times the running current, so the generator has to supply it without dropping voltage.
Can a 5,000-watt generator run a house?
It runs the essentials: a fridge, a furnace blower, a well pump, lights, internet and charging, about 3,200 watts of load. It will not run a central AC, an electric water heater or an electric dryer.
Do I need to add up starting watts for every appliance?
No. Count the running watts of everything, then add the starting watts of the single largest motor only. Motors rarely start in the same second, and sizing for all of them at once doubles the price for no benefit.
How much headroom should I add?
20% at minimum, 25% for most homes, 30% if you have a well pump or a big AC. The margin covers elevation, heat, age and the voltage sag during a motor start.
Can I plug a generator into my house outlet?
No. Backfeeding through a dryer or range outlet is illegal in most states and lethal to utility crews. A transfer switch or a panel interlock, installed by a licensed electrician, is the only safe connection.
How much does a transfer switch cost?
A manual transfer switch with six to ten circuits runs $300 to $800 installed. A whole-panel interlock kit runs $200 to $500 plus labor, and both need a permit in most jurisdictions.
How long will a generator run on a tank of gas?
A 5,000-watt unit at half load burns about 0.5 gallons an hour, so a 6-gallon tank lasts roughly 12 hours. A 2,500-watt unit at the same load runs about 20 hours on the same fuel.
Is an inverter generator worth the extra money?
For electronics, yes. Total harmonic distortion under 3% keeps furnace control boards, TVs and laptops happy, and the units run 52 to 62 dB instead of 74. Expect to pay 30% to 50% more per watt.
Can I run a generator in the garage with the door open?
No. Carbon monoxide builds faster than the door clears it, and the exhaust can drift into the house. Keep the unit at least 20 feet from doors, windows and vents, outdoors, with the exhaust pointed away.
Will a generator run my central air conditioner?
A 3-ton central AC needs about 3,500 running watts and 6,000 at startup, so a 7,500-watt unit can carry it alone. Running the AC plus the rest of the house usually needs 11,000 watts or a soft-start kit.
What size generator runs a well pump?
A 1/2 hp pump runs on 1,000 watts and starts at 2,000, so any unit above 2,500 watts handles it. Deep wells with 1 hp or larger pumps need 3,000 to 4,000 running watts and a matching surge.
Does a bigger generator use more fuel if I use less power?
Yes, at light load. A 10,500-watt unit burns about 1 gallon an hour at half load against 0.5 for a 5,000-watt unit, and an oversized engine running at 20% load is the least efficient way to make a kilowatt.
How often should I test a generator?
Run it under load for 30 minutes every three months, and change the oil after the first 5 hours and then every 50 hours. Stale gasoline is the reason most units fail to start after two years in a shed.
Spotted a wrong number or a broken result?
More Home Improvement tools
- ADU Cost Calculator
- Acreage Calculator
- Aggregate Cost Calculator
- Air Conditioner Room Size & BTU Calculator
- Aluminum Fence Cost Calculator
- Asphalt Calculator
- Awning Cost Calculator
- Bathtub vs Shower Footprint Calculator
- Bleach Dilution Calculator
- Block Mortar Calculator
- Board Footage Calculator
- Board and Batten Layout Calculator
- Board and Batten Siding Calculator
- Board on Board Fence Calculator
- Borax Ant Killer Calculator
- Brick Calculator
Fee schedules, rates and rules change without notice. Always confirm important figures with the official source before you rely on them.